Heat pumps and refrigerators

Model refrigerators and heat pumps as reversed heat engines and calculate COP in cooling and heating modes.

Reading settings
  • University Physics Year 1
On this page

Reading settings

Text size, line spacing and reading width for your lessons.

Text size
Line spacing
Reading width

Live preview

Take a moment to read at your own pace. Choose the text size and spacing that feel comfortable for you.

Pause after each idea, then explain it in your own words before moving on.

Narrower lines take effect when the screen has room.

Enlarged diagram

A refrigerator, air conditioner and heating heat pump share an energy-transfer idea: work enables heat to move from a colder region to a warmer one. The useful benefit depends on which region you want to cool or heat. A large heat output per joule of work is not energy creation, but it still has a temperature-dependent upper bound.

Build on cyclic energy accounting and the Carnot engine. Use positive magnitudes Qc extracted from the cold side, Qₕ delivered to the hot side and Wᵢₙ supplied as work. Over a complete cycle with these as the only transfers, Qₕ = Qc + Wᵢₙ.

Match the numerator to the purpose

Cooling COP is Kc = Qc/Wᵢₙ; heating COP is Kₕ = Qₕ/Wᵢₙ. For the same complete energy account, Kₕ = Kc + 1. An engine efficiency asks how much work comes from absorbed heat, while COP asks how much heat is moved or delivered per work input. There is no common requirement that both ratios be below one.

Draw the boundary around the supplied device and state what is included in work input. Fan power, defrost, leaks, startup storage and useful heating losses can change an installation’s measured COP. Do not apply Kₕ-Kc = 1 to two reported ratings from different test conditions or to quantities that omit different channels. Rates can replace per-cycle energies in a consistent steady account.

Short worked examples

Refrigerator performance

Worked example 1

Cooling and room heating

Problem

A refrigerator extracts 2.4 kJ per cycle using 0.8 kJ of work. Find its cooling COP and heat rejected to the room per cycle.
Show full solution
  1. Use extracted heat as the benefit

    Method

    Calculate Kc = Qc/Wᵢₙ.

    Reason

    The desired effect is cooling the cold space, so delivered room heat is not the numerator.

    Working

    Answer

    Kc = Qc/Wᵢₙ = 2.4/0.8 = 3.0.
  2. Account for the work input

    Working

    Answer

    The cooling COP is 3.0. The room receives both extracted heat and work: Qₕ = Qc + Wᵢₙ = 3.2 kJ. Thus the room gains more heat than the refrigerator removes from its interior.

Heating-mode performance

Worked example 2

Heating COP

Problem

A heat pump delivers 5.0 kJ per cycle with work input 1.25 kJ. Find its heating COP and the cooling COP for that cycle.
Show full solution
  1. Choose the heating numerator

    Method

    Divide Qₕ by Wᵢₙ.

    Reason

    The heating benefit includes heat moved from the cold side plus energy supplied as work.

    Working

    Answer

    Kₕ = 5.0/1.25 = 4.0.
  2. Use the COP difference

    Working

    Answer

    Kₕ = 5.0/1.25 = 4.0, Kc = Kₕ-1 = 3.0. Both are dimensionless; Kₕ-Kc = 1 accounts for the supplied work.


Derive the reversible temperature bound

For the combined cyclic pump and two fixed reservoirs, S_gen = Qₕ/Tₕ-Qc/Tc ≥ 0. Use Qc = Qₕ-Wᵢₙ to obtain Wᵢₙ ≥ Qₕ(Tₕ-Tc)/Tₕ, Kₕ ≤ Tₕ/(Tₕ-Tc). Similarly, Kc ≤ Tc/(Tₕ-Tc). These are reversible Carnot limits with Tₕ > Tc > 0 in kelvin. Real heat transfer, friction and other entropy generation increase the required input for the same useful transfer and reservoir temperatures.

A smaller temperature lift raises the ideal COP bound, but it does not guarantee the same improvement for every device: operating conditions, capacity and losses also matter. A formally divergent bound as Tₕ-Tc → 0 is not a promise of finite useful transfer with zero work in a practical device.

Guided practice 3

Test an attractive heat-pump rating

About 8 min

Problem

A cyclic heat pump exchanges heat only with reservoirs at 270 K and 300 K. A claimed cycle delivers 6000 J to the hot side using 300 J of work, with no other transfers or net energy storage. Find the claimed heating COP, its reversible upper bound and the minimum possible work input for that delivered heat. Does an internally consistent energy balance make the claim feasible?

Work through the model, then compare your reasoning

Unit: J

Hints

Hint 1

Check the model

The first law gives the extracted cold-side heat. The second law limits how little work can produce that transfer.
Show solution step by step
  1. Calculate the claim and ceiling

    Method

    Compare Qₕ/Wᵢₙ with Tₕ/(Tₕ-Tc).

    Reason

    COP above one is allowed, but COP above the reversible bound is not.

    Working

    Answer

    The claimed COP is 6000/300 = 20. The reversible bound is 300/(300-270) = 10, so the minimum possible input is 6000/10 = 600 J. The claim asks for half that minimum.

  2. Check the complete transfer account

    Method

    Use Qc = Qₕ-Wᵢₙ.

    Reason

    An energy balance can close while total entropy changes in a forbidden direction.

    Working

    Answer

    The claim extracts 5700 J, so energy conservation closes: 6000 = 5700 + 300. But S_gen = 6000/300-5700/270 = -1.11… J/K is negative. The claim is incompatible with the stated two-reservoir cycle. Recheck the rating conditions, quantities and boundary before drawing a device conclusion.

Trace where the rejected heat goes

A refrigerator warms its surroundings with the heat extracted from its interior plus the work input. It can cool a separate space only when its heat rejection is routed somewhere else. For a larger boundary containing both cold and hot sides, those heat transfers are internal and cancel; the external work input still adds energy to the combined system.

This boundary reasoning also prevents double-counting a pump’s useful outputs. A heating calculation uses heat delivered to the intended space, with any delivery losses accounted for. A cooling calculation uses heat actually removed from the intended cold space, not the hot-side total.

Choose the boundary for an open refrigerator

Check your understanding 1

An open refrigerator operates inside a thermally insulated room. Over an interval, its cyclic mechanism extracts 2400 J from room air, rejects 3200 J back into the room and receives 800 J of electrical work from outside. Neglect changes in macroscopic kinetic and potential energy and any storage change in the refrigerator itself. Find net external heat and work into the room and refrigerator together, and their combined internal-energy change. A colleague expects room cooling because the device has cooling COP 3: identify the incorrect boundary argument.

Unit: J
Unit: J
Unit: J

Show answer

For the combined room–refrigerator boundary, the 2400 J and 3200 J transfers are internal. Net external heat is zero and electrical work input is 800 J, so the combined internal energy increases by 800 J. Equivalently, room air loses 2400 J but receives 3200 J, a net gain of 800 J. COP 3 describes removal from the cold side, but both sides are inside the same room. It does not imply net room cooling; in this model the room gains energy. A closed refrigerated compartment and heat rejection to a separate surrounding space answer a different boundary question.

Practice set

Check your understanding 2

A heat pump delivers 6.0 kJ and extracts 4.5 kJ per cycle. Find its work input, heating COP and cooling COP.

Show hint
Use the cycle balance to find the common COP denominator.
Show answer
Wᵢₙ = 6.0-4.5 = 1.5 kJ; Kₕ = 6.0/1.5 = 4.0 and Kc = 4.5/1.5 = 3.0. Their difference is one, as required.

Check your understanding 3

A refrigerator has cooling COP 2.5 and uses 400 J per cycle. Find the heat extracted per cycle.

Show hint
Rearrange Kc = Qc/Wᵢₙ.
Show answer
Qc = KcWᵢₙ = 2.5(400) = 1000 J per cycle. COP multiplies work input to give the useful cooling heat.

Check your understanding 4

Does a heating COP of 1.8 violate energy conservation? Explain.

Show hint
Delivered heat has two sources.
Show answer
No. For each joule of work, the pump delivers 1.8 J by also extracting 0.8 J from the cold side. The balance Qₕ = Qc + Wᵢₙ is satisfied.

Check your understanding 5

With indoor temperature fixed, what usually happens to a heat pump’s heating COP when the colder outside air warms closer to indoor temperature?

Show hint
Consider the smaller temperature lift.

Show answer

Heating COP usually increases: the smaller temperature lift requires less work per unit of delivered heat. Actual performance also depends on the device and operating conditions.

What to keep

Heating and cooling COP use different useful heat transfers. A complete cyclic balance gives their difference; the reservoir temperatures impose stronger Carnot bounds. Follow every transfer across the chosen boundary before interpreting a rating or a room-heating claim.

Spotted an error? Report a correction

Syllabus and review details

No official syllabus alignment is listed for this lesson.

Back to top